文档介绍:第三届中国 LNG 论坛论文编号:1260702
中山市天然气高压输配系统中抗震措施的应用与研究
王引平 1 王普2
(,广东中山 528403;,广东中山 528400;)
摘要:根据地震引起的燃气管线事故分析,结合中山市地质条件与国内外燃气管线抗震减震的先进办法。论
述了抗震设计在场站选址、管线路由、管道材料及监控系统等方面的应用,对液化土层区域进行了校核计算分析,
达到在预估的罕遇地震下天然气输配系统安全运行的抗震设防目标。
关键词:城市燃气;防震减震;抗震设计;液化土层
Application and Research on the Anti-seismic Measures of High Pressure
Distribution System for Natural Gas in Zhongshan City
WANG Yinping WANG Pu
Abstract : According to the analysis of the gas pipelines accidents triggered by the earthquake,
combined with zhongshan geological conditions and the advanced gas pipeline anti-seismic measures at
home and abroad , the application of monitoring system in stations location , pipeline route, piping
materials , monitoring system are discussed,soil liquefaction zone has been checked , calculated and
that we can achieve the seismic fortification goals of natural gas transmission and
distribution system safety operation in the forseeable rarely earthquake.
Key words: City gas Quakeproof Aseismic design Soil liquefaction
2008年5月12日发生了汶川大地震,此次地震对汶川及其周边县市的燃气输
配系统均造成了不同程度的破坏,其震害经验表明,城市燃气管网在地震
中极易损坏,泄漏引发的大火成为最严重的次生灾害之一[1]。城市燃气工
程在城市基础设施中有着极其重要的地位,关系到地震时对城市居民生命
财产造成危害的大小和灾后重建的难易。重视城市燃气输配系统的抗震设
计,严格按照现行有关抗震设计规范进行抗震设计计算与分析[2]、校核、
施工、使用和建立SUPREME地震实时监控系统[3]的燃气工程,在遭遇比当
地设防烈度高一度的地震作用下,可以达到在预估的罕遇地震下保障天然
气输配系统安全运行的抗震设防目标,将地震的损失降到最低限度。
1. 中山市的地质及地震
中山市地处珠江三角洲沉积区,大部分为第四纪覆盖,基底岩石断裂多
隐伏。据资料分析,该区为潜在震源区。根据国家质量技术监督局 2001 年
发布的《中国地震动参数区规划》(GB18306-2001),沿线抗震设防烈度为
Ⅶ度,设计地震动峰值加速度为 ,地震动反应谱特征周期为 。
中山市天然气高压管线系统分布状况及地质灾害分布概况如图 1 所示:
图 1 中山市天然气高压输配系统与地质灾害分布概况图
2. 地震引起的管道事故分析
根据地质报告及地震划分图,中山市的天然气高压管道经过地区抗震
设防烈度均为Ⅶ度,地震对输配系统破坏造成的事故主要有:建筑物砸坏
设备、管道,砸伤工作人员;造成电力、通信系统中断、毁坏;对管道
遭受腐蚀或焊接质量较差的薄弱部分产生破坏作用;管线错位、拉断、
撞击、摩擦着火;阀门、法兰、垫片破损,天然气泄漏;地震产生的电
磁场变化,干扰控制器及仪表正常工作,进而引发事故的发生。
3. 抗震设计在中山市天然气输配系统中的应用
根据中山市地质条件及地震对输配系统破坏造成的事故类型,结合国
内外燃气管线抗震减震的先进办法,相应的抗震设计在中山市天然气输
配系统场站选址、管线路由、管道材料、管道壁厚及监控系统等方面的
得到了广泛应用,以期达到在预估的