文档介绍:摘要
本次设计的城市污水处理厂的工程规模达200000m3/d。为使出水达到国家综合污水排放标准(GB 18918-2002)一级B类标准,同时贯彻执行“三同时”制度,故本次设计采用处理效率较高的卡鲁塞尔2000 型氧化沟处理工艺。该工艺不仅能去除BOD5与COD,而且还具备硝化和一定的脱氮除磷作用,使出水NH3-N低于排放标准。
本工程污水处理工艺为Carrousel 2000氧化沟工艺,污泥处理工艺为污泥浓缩脱水工艺。
关键词:城市污水;卡鲁塞尔2000型氧化沟;污泥浓缩脱水
The scale of the urban wastewater treatment plant project in the thesis is 200000m3 / d. To reach prehensive National Sewage Discharge Standard (GB 18918-2002) Class A Type B, while implementing the "The Three Simultaneousnesses" system, high efficiency Carrousel 2000 Oxidation Ditch Treatment process is used in this project. The process can remove BOD5 and COD as well as is of certain ability of nitrification and nitrogen and phosphorus removal. In this way, the content of NH3-N in the sewage can stay below the emission standard.
Wastewater treatment process for this project is Carrousel 2000 Oxidation Ditch Treatment process. Sludge treatment process is sludge concentration and dewatering process.
Keywords: urban wastewater, Carrousel 2000 Oxidation Ditch, sludge concentration and dewatering.
朗读
显示对应的拉丁字符的拼音
 
字典- 查看字典详细内容
目录
前言 5
第一章城市污水处理厂设计概况 6
设计概况 6
设计原则、范围与依据 6
工程规模和处理水质要求 8
工艺流程的比较及选择 8
工艺流程的比较 8
工艺流程的选择 12
本设计工艺流程的确定 14
水处理构筑物设计说明 14
粗格栅 14
污水提升泵房 15
细格栅 15
曝气沉砂池 15
氧化沟 16
二沉池 16
接触消毒池 18
污泥处理构筑物设计说明 19
污泥泵站 20
污泥浓缩池 20
储泥池 20
脱水机房 21
平面与高程布置 21
平面布置 21
高程布置 23
第二章城市污水处理厂设计计算书 25
泵前粗格栅 25
设计参数 25
设计计算 25
污水提升泵房 27
设计计算 27
泵的扬程计算 28
泵后细格栅 29
设计参数 29
设计计算 29
曝气沉砂池 31
设计参数 31
设计计算 31
氧化沟 34
34
设计要点 34
设计计算 36
二沉池 41
设计参数 41
设计计算 41
接触消毒池 46
设计参数 46
设计计算 46
巴式计量槽 47
污泥泵房 47
污泥浓缩池 48
设计参数 48
设计计算 49
储泥池 51
脱水机房 51
堰式配