文档介绍:轴流式引风机失速原因分析及预防措施
张乐君
浙江浙能兰溪发电有限责任公司浙江省金华市 321100
摘要:针对浙能兰溪电厂锅炉引风机曾多次发生失速的情况,在介绍轴流引风机失速机理基础上, 根据实测数据对引风机失速原因进行了分析, 认为空预器堵塞严重导致管路阻力特性变化、引风机静叶开度过大是引风机失速的原因, 并提出了引风机失速的处理及预防措施。
关键词: 轴流式引风机;失速;静叶可调;预防措施;
Abstract: The mechanism about stall of axial fan is introduced in this paper, it is analyzed that why the boiler induced draft fan will stall based on the measured data, in connection with that the boiler induced draft fan have stalled times in Lanxi power plant,the stalling cause of boiler induced draft fan is concluded that pipeline’s resistance changed because of ash clogging in regenerative air heater and the angle of fixed blade is over opened. The paper also puts forward stall of induced draft fan operating and opinions to avoid fan stall.
Keywords:axial flow induced draft fan; stall;blade adjustable; prevention measures;
引言
浙能兰溪电厂#1~#4号机组额定容量为600 MW,锅炉容量为1903 t/h,是北京巴威公司制造的超临界参数变压运行、一次中间再热、单炉膛、平衡通风,露天布置,固态排渣,全悬吊结构∏型锅炉。锅炉配有2台三分仓回转式空预器,2台型号为AN35e6(V13+4°)的静叶可调轴流式引风机,静叶调节范围为-75°~31°(对应静叶开度0%~100%),设计风量为482 m3/s,设计静压为4 835 Pa,风机转速为595 r/min。我公司配有脱硫系统,引风机后串接增压风机。浙能兰溪电厂1号机组于2006年投产发电;2号机组于2006年;3号机组于2006年投产发电;4号机组于2007年投产发电。1号机和2号机分别于2007年5月和2007年10月进行了A级检修,3号机和4号机未进行过A检修。在2008年1月~2008年2月期间,4台锅炉的引风机都曾多次发生失速现象,一度影响了机组带负荷能力,经过技术人员分析,认为引风机失速的主要原因是空预器堵灰严重,风道阻力特性变化使引风机动静开度过大、运行在不稳定区所致
。于是对1号炉和4炉的空预器进行了在线水冲洗,使空预器压差减小,减少了引风机失速的发生,由于冲洗技术的差别(1号炉的空预器为本厂设备部冲洗,4号炉的空预器为专业公司冲洗)1号炉的空预器压