文档介绍:变流量时地埋管换热器的性能评价
华北科技学院李琼李琼(),女,讲师,硕士,研究方向:地源热泵
通讯地址:北京东燕郊206信箱华北科技学院土木工程系建环教研室,邮政编码:101601;电话:010-61594914-8052
Email:hdliqiong@
刘宏伟崔蕾
摘要综述了现有地埋管换热器性能的评价方法,根据变水流量时地埋管换热特点,综合考虑动量传递相似律与热量传递规律,采用单位管长换热量与泵耗功率相结合的热性能评价法对地埋管换热器冬季工况时的性能作出评价。
关键词地埋管换热器;变流量;性能评价
分类号TU831
Performance Evaluation of Ground Heat Exchanger When Water Volume was Changed
Li Qiong, Liu Hongwei , Cui Lei
(North China Institute of Science and Technology)
Abstract: This paper summarizes evaluation methods of performance about heat exchanger. The evaluation of ground heat exchanger was evaluated in winter condition by prehensive method –combination of unit tube length for heat and pump power consumption, based on the heat transfer characteristics when water volume was changed, and consideration of momentum transfer similarity law and heat transfer law.
Key words: ground heat exchanger; variable water volume; performance evaluation
1 引言
地埋管换热器是地源热泵空调系统的重点和核心设备,也是地源热泵空调系统不同于传统空调系统的关键设备。地埋管换热器传热过程与通常的换热器不同,它不是两种流体之间的换热,而是埋管中的流体与周围土壤间的换热。这种换热过程特殊且复杂,以往传统换热器的研究并没有现成的经验可以借鉴。目前很多学者对地埋管换热器的传热性能进行了大量的理论分析与实验研究,得出地源热泵节能的一般性结论,而对地埋管换热器的性能评价方法较单一。
地埋管换热器的性能评价,大多采用单位管长换热量,重庆大学[1]采用有效换热率评价,这些评价方法都属于单一性能评价方法,而且是以热力学第一定律为基础的。大连理工大学[3]提出采用火用效率分析,虽然此方法能更准确地反映热量交换过程中能量在质的损失,在设计过程中可用火用效率来判断换热器的性能,作为进一步改善的依据,但在工程上缺乏实用性。本文采用单位管长换热量与泵耗功率相结合的性能评价法,反映变流量对地埋管换热器的换热性能的影响。
2地埋管换热器的性能评价方法
一定结构的地埋管换热器,改变地埋管内循环水的流量后,地