文档介绍:Dynamic Dilution Olfactometer Based on Triangle
Odor Bag Method
Liu Weiling1,2 Xu Yan2 Li Changjiang1 Zou Kehua1 Bao Jingling1
1
1. State Environmental Protection Key Laboratory of Odor Wang Liyuan
Tianjin Academy of Environmental Sciences 2. School of Mechanical Engineering
Tianjin, CHINA Hebei university of Technology
Goodtimeuk@ Tianjin, CHINA
Abstract—The aim of this work is to establish a Dynamic Dilution method in which “odor index”(logarithm of odor
olfactometer based on GB. The triangle odor bag method is concentration, multiplied by ten) is measured. In some sense,
described and used in the design of Dynamic Dilution the triangle bags method is not only a measuring method, but
olfactometer. In this paper, we provide detailed instructions for also an important form to propagandize odor pollution
construction of an air dilution olfactometer capable of generating knowledge to people and call on them to attend in environment
neat odorants and binary mixtures at a range of known
concentration. puterized Dynamic Olfactometer can protection work.
realize with 9 dilution levels and dilution ratios 10 to 100,000. The Olfactometer uses a panel of 8 people (assessors) to
The central part is mass flow meter, integrated LabVIEW evaluate ‘air’ being presented at 3 ports. 2 ports present clean,
platform with Microsoft® Access database.