文档介绍:暖通空调 HV &A C 2008 年第 38 卷第 2 期专题研讨· 5 ·
污水换热器内污垢
生长特性实验研究
2
哈尔滨工业大学李鑫☆孙德兴张承虎吴荣华
摘要介绍了污垢生长监测方法,并以哈尔滨望江宾馆和北京悦都酒店为测试对象,对换
热器内污垢生长作了实时监测,得出了污垢热阻随时间的变化规律、污垢的平衡厚度和换热器
热阻与流速的关系以及换热器结垢前后总传热系数的比。
关键词污水换热器污垢生长污垢热阻流速
Exp e ri m e nt of f o uli n g gro wt h
c h a r a c t e risti c s i n s e w a g e h e a t e x c h a n g e rs
By Li Xin ★, Sun Dexing , Zhang Chenghu and Wu Ronghua
Abst ra ct Presents t he inspecting met hods of f ouling growt h and inspects in real time t he growt h of
f ouling in t he sewage heat exchangers in Harbin Wangjiang hotel and Beijing Yuedu hotel. Obtains t he
variation p attern of t he f ouling heat resistance wit h time , t he relations between t he balance thickness of
f ouling and t he velocity and between t he heat resistance of t he heat exchanger and t he velocity , and a ratio of
t he total heat transf er coefficient bef ore f ouling f orming to t hat af ter f ouling f orming.
Keywords sewage heat exchanger , f ouling growt h , f ouling heat resistance , velocity
★ Harbin Institute of Technology , Harbin , China
①
0 引言验,为此本文以哈尔滨望江宾馆和北京悦都酒店两
利用地表水(城市污水、江河湖水、海水等) 作个实际工程为实验对象,对污水换热器内的污垢生
为热泵热源/ 汇为建筑供暖供冷具有重要的节能、长规律进行研究。
环保及经济价值[1 - 2 ] ,合理、规范的系统设计是保 1 监测方法
证系统可靠、经济运行的前提。由于城市污水、江目前污垢生长的监测方法主要有热阻法、传热
河湖水、海水等的利用均存在系统阻塞、污染、取水系数法、温差法。本次实验采用最常用的热阻法进
等问题[3 ] ,故将其划分为一类,统称地表水源。行监测。
自 20 世纪 70 年代以来,地表水源热泵几乎同污垢热阻法是最传统、最经典的污垢