文档介绍:化学工程师
年第期
Sum 168 Chemical Engineer 2009 9
文章编号: ( )
生 1002-1124 2009 09-0053-02
产
与冷却水换热器结垢和腐蚀的
技
术
改原因及处理措施
造
左玖玲
(中煤龙化集团公司哈尔滨煤化工有限公司,黑龙江哈尔滨)
150001
摘要:阐述了冷却水换热器结垢和腐蚀的原因,并对其危害进行了介绍;探讨了结垢和腐蚀的处理措
施,为解决冷却水换热器结垢和腐蚀问题提供了借鉴和指导
。
关键词:冷却水换热器;结垢;腐蚀
中图分类号: 文献标识码:
A
Causes and treatment measures of fouling and corrosion on the cooling water heat exchanger
ZUO Jiu-ling
( , , )
Harbin Coal Chemieal Industry Co., Ltd., Heilongjiang Coal Chemical Industry Group China Coal Harbin 150001,China
Abstract: The causes of fouling and corrosion on the cooling water heat exchanger were expounded and its
hazards were introduced in this paper. The treatment measures of fouling and corrosion was discussed to provide
reference and guidance for resolving the fouling and corrosion of cooling water heat exchanger.
Key words: cooling water heat exchanger; fouling; corrosion
在化工生产过程中,各类介质的热量交换均离为不溶于水的的水合物,在水中产生大量铁
Fe2O3
不开重要的化工设备冷却水换热器大多数冷氧化物沉淀以及建立氧浓差腐蚀电池,腐蚀金属
———。。
却水换热器在换热过程中都存在着结垢堵塞和腐循环水系统中的藻类主要有绿藻蓝藻和硅藻它
、。
蚀问题,常出现因传热不够而被迫停车清洗或者换们常在水中形成金属表面差异腐蚀电池而导致沉
热器的更换,严重时会影响安全生产的进行因积物下腐蚀块状的还会堵塞换热器中的管路,减
[ 1,2 ]。。
此,本文针对冷却水换热器结垢和腐蚀的原因,探少水的流量,从而降低换热效率
。
讨了常见的结垢和腐蚀的处理措施,为解决冷却水结晶污垢
换热器结垢和腐蚀问题提供借鉴和指导
。在冷却水循环系统中,随着水分的蒸发,水中
溶解的盐类(如重碳酸盐硫酸盐硅酸盐等)的浓
结垢的原因、、
1 度增高,部分盐类因过饱和而析出,而某些盐类则
因通过换热器传热表面时受热分解产生沉淀这些
。
颗粒污垢水垢由无机盐组成结晶致密,被