文档介绍:循环水排污水处理系统设计计算
循环水排污水处理系统设计计算
摘要:针对云浮电厂C厂2×300MW“上大压小”循环流化床燃煤发电工程循环水排污水处理系统进行设计计算,选择合理的浓缩倍率,计算循环水排污水量,从而对采用的工艺系统进行设备选型。
关键词: 循环水排污水计算浓缩倍率设备选型
Design and calculation of blowdown water of circulating water treatment system
Wangxusheng
(Yunnan Electric Power Design Institute ,Yunnan,Kunming,650051)
Abstract:Design and calculation are carried out for blowdown water of circulating water treatment system for Yunfu power plant C 2×300MW circulating fluidized bed coal-fired power generation project, in order to select reasonable concentration rate and calculate blowdown water capacity of circulating water, and then to carry out selection of equipment model for adopted process system.
Keyword: blowdown water of circulating watercalculationconcentrate rateselection of equipment model
1工程概况
云浮电厂C厂2×300MW“上大压小”循环流化床燃煤发电工程电厂供水水源为西江水,全年的水质较为稳定,含盐量、悬浮物含量低。现有水质资料显示:~。
循环水系统基本数据(单台机组):
循环水量:38365m3/h
蒸发损失:461m3/h
风吹损失:20m3/h
2系统流程
本工程循环水排污水处理方案采用弱酸离子交换处理方案。
循环水排污处理方案系统流程如下:
杀菌剂凝聚剂、助凝剂
循环水排污水→机械搅拌澄清池→双滤料过滤器→顺流弱酸阳床→软化水池→循环水前池。
3循环水浓缩倍率的确定
浓缩倍率与排污量的关系为:
N=Qm/(Qb+Qw)
式中:Qm=Qe+Qb+Qw
Qm-----补充水量(m3/h)
Qe-----蒸发损失水量(m3/h)
Qb-----排污损失水量(m3/h)
Qw-----风吹损失水量(m3/h)
单台机组浓缩倍率与排污水量的关系如下图:
由上表可见,N≥4的区域,随着浓缩倍率的提高,排污水量的下降幅度趋缓。
根据已有工程经验,选择合适的阻垢剂,控制浓缩后循环水总硬度≤10mmol/L,可以使系统长期稳定高效运行。