文档介绍:/ - 一
^nling智能液位显示仪
Intelligent Liquid Level
Instrument
1智能水位识别 1标尺和告警点可设置
1 Intelligent water level identification情况在面板标尺上显示出来。
Due to the adoption of intelligent water level identification technology, correct water level value can be still obtained under the condition that part of the electrode is damaged and meanwhile the damage condition of the electrode can be immediately displayed on the scale plate of the panel.
高抗干扰能力
Strong interference immunity capabilitv
电极测试部分采用了光电隔离和数字滤菠技术,并采用带回差的电极状态判别法,大大提高 抗干扰能力;输出环节采用恣逐苦警,防止在瞬间强干扰的情况下产生误告警,同时彻底解决了老 式仪表在开机瞬间产生误告警的问题。
Optoelectronic isolation technology and digital filtering technology are adopted for electrode testing part, and meanwhile the electrode state judgment method with return difference is also adopted, thus to significantly improve the interference immunity capability; delayed alarm is adopted for the output link in order to prevent false alarms from being generated at the strong interference moment and accordingly completely solve the problem of the generation of false alarm at the startup moment of old instruments.
高可靠性
High reliability
除上面提到的电极容错技术和抗干扰能力外,仪表本身由超大规模集成电路构成,电路设计 简捷,硬件可靠性很高。
Besides the electrode fault-tolerant technology and interference immunity capability mentioned above, this instrument also has the features of super-large-scale integration composition, convenient and simple circuit design, and high hardware reliability.
标尺数字和告警点可设定
Configurable scale figure and alarm point
可以自由设置水位标尺数字和告警点位置,非常灵活直观。
The scale figure and the alarm point of water level can be freely set, thus to make this instrument have the features of flexible setting and visual display.
电极测试功能
Electrode testing fujiction
老式仪表只有当电极已损坏时才可以被发现,而电极的损坏往往是一个缓变过程(如结垢、 腐蚀等)。本仪表能对每一个电极单独进行测试,测出电极对测量筒体的电阻,这种测试可以使您 及时发现异常的电极,或帮助您决定一组电极是否需要清洗或更换,也可为水汽阻临界值的调整提 供参考。
For the old instruments, only the damaged electrode can be discovered, but the electrode damage process is a slow change process (including scaling