文档介绍:PHC 管桩桩基偏位事故的分析和处理 PHC 管桩桩基偏位事故的分析和处理[ 摘要] 本文结合一工程实例分析了 PHC 管桩基础在基坑开挖后出现偏位和断裂的原因, 提出了在施工和设计等方面的处理措施, 并介绍了应用锚杆静压钢管桩和钻孔灌注桩对桩基进行补强的措施以及补强处理后的效果,可供有关工程技术人员参考借鉴。[ 关键词] PHC 管桩;偏位;钻孔灌注桩;锚杆静压桩[ 中图分类号] [ 文献标识码]A Analysis and Treatment of Deviation Accident of PHC Pipe Pile Foundation Abstract: Combined with a practical instance of construction, the causes of deviation and fracture on PHC pipe pile foundation are analyzed. In addition, the measures to remedy this kind of accidents also are presented from the aspects of construction and design. Some methods that apply cast-in-place pile and anchored and jacked pile to strengthen the foundation are introduced in this paper. Furthermore, the effect of reinforcement is estimated. Key Words: PHC Pipe Pile, deviation, cast-in-place pile, anchored and jacked pile 近年来, PHC 管桩( 高强预应力混凝土管桩) 由于具有桩身成型质量好、混凝土强度高、单桩承载力大、耐冲击性能好、穿透力强、价格便宜、施工快捷且采取静压施工时对周围环境影响小等优点而被广泛应用于多层及高层建筑结构的基础工程中。但在土性复杂特别是土质较差的软弱地基的基坑开挖施工过程中, 由于桩身为空心, 其抗剪和抗裂性能相对较差, 如果土方施工中基坑围护措施不到位或挖土方法不当, 常会发生桩体偏位、桩身断裂等事故, 从而大大削弱了基础的承载力。因此发生此种情况后如何对基础进行加固补强就成为施工中急待解决的一个难题。 1 工程概况某工程基坑占地面积约 20000m2 ,总建筑面积约 90000m2 ,各号房结构均为剪力墙结构体系, 建筑场地类别为Ⅲ类, 基础设计等级为乙级。桩基础采用桩径 500mm 的 PHC 管桩, 基坑一般挖深为 , 最深达 m 。桩长 29m、 32m和 37m 不等,采取静压方式,桩端要求进入持力层不小于 m, 要求单桩竖向极限承载力为 2800kN ,以②- 4 层粉细砂为桩端持力层。基坑开挖范围内地质分布情况如表1 所示。该工程基坑所采取的支护形式为深层搅拌桩, 桩长 4m, 宽度为 m, 桩底标高为- , 沿整个大地下室四周布置。该工程 X 号房基坑先行开挖,X 号房基坑面