文档介绍:word
word
1 / 105
word
环境空气检测作业指导书
word
word
2 / 105
word
中铁西北科学研究院
工程检测试验中心
二〇一五年
目录
一、环境空气氮氧化物的测定1
二、空气质量恶臭的测定9
三、环境空气二氧化硫的测定14
四、环境空气二硫化碳的测定22
五、环境空气一氧化碳的测定25
六、环境空气总悬浮物颗粒的测定27
word
word
3 / 105
word
七、环境空气PM10和PM的测定32
八、硫化氢的测定···········································································································37
九、环境空气氟化物的测定·····························································································43
十、环境空气和废气氨的测定纳氏试剂分光光度法···············································48
十一、环境空气氨的测定次氯酸钠-水杨酸分光光度法···········································54
十二、固定污染源废气苯可溶物的测定·······························································59
十三、废气铬酸雾的测定····················································································64
十四、硫酸雾的测定·························································································67
一、环境空气氮氧化物的测定
一、执行标准
环境空气氮氧化物(一氧化氮和二氧化氮)的测定盐酸萘乙二胺分光光度法 HJ 479-2009。
二、适用X围
1、本标准适用于环境空气中氮氧化物、二氧化氮、一氧化氮的测定。
2、µg/10ml  吸收液。当吸收液总体积为10ml,采样体积为24L时,空气中氮氧化物的检出限为/m3。当吸收液总体积为 50ml,采样体积288L 时,空气中氮氧化物的检出限为3,本标准测定环境空气中氮氧化物的测定X围为  mg/m33。
三、干扰与消除
1、空气中二氧化硫浓度为氮氧化物浓度 30 倍时,对二氧化氮的测定产生负干扰。
2、空气中过氧乙酰硝酸酯〔PAN〕对二氧化氮的测定产生正干扰。
3、空气中臭氧浓度超过3 时,对二氧化氮的测定产生负干扰。采样时在采样瓶入口端串接一段(15~20)cm 长的硅橡胶管,可排除干扰。
四、测定原理
空气中的二氧化氮被串联的第一支吸收瓶中的吸收液吸收并反响生成粉红色偶氮染料。空气中的一氧化氮不与吸收液反响,通过氧化管时被酸性高锰酸钾溶液氧化为二氧化氮,被串联的第二支吸收瓶中的吸收液吸收并反响生成粉红色偶氮染料。生成的偶氮染料在波长  540nm  处的吸光度与二氧化氮的含量成正比。分别测定第一支和第二支吸收瓶中样品的吸光度,计算两支吸收瓶内二氧化氮和一氧化氮的质量浓度,二者之和即为氮氧化物的质量浓度
word
word
2 / 105
word
〔以二氧化氮计〕。
五、仪器设备
1、常用的实验室仪器。
2、分光光度计。
3、空气采样器:流量X围~。采样流量为  时,相对误差小于±5%。
4、恒温、半自动连续空气采样器:采样流量为  时,相对误差小于±5%,能将吸收液温度保持在 20℃±4℃。采样管:硼硅玻璃管、不锈钢管、聚四氟乙烯管或硅胶管,内径约为 6mm,尽可能短些,任何情况下不得超过 2m,配有朝下的空气入口。
5、吸收瓶:可装 10ml、25ml 或 50ml 吸收液的多孔玻板吸收瓶,液柱高度不低于 80mm。吸收瓶的玻板阻力、气泡分散的均匀性与采样效率按本标准附录 A 检查。使用棕色吸收瓶或采样过程中吸收瓶外罩黑色避光罩。新的多孔玻板吸收瓶或使用后的多孔玻板吸收瓶,应用〔1+1〕HCl 浸泡 24h 以上,用清水洗净。
6、氧化瓶: