文档介绍:等离子点火装置对 1000MW 锅炉运行的影响及对策
王如良
国电浙江北仑第一发电有限公司,浙江宁波 315800
THE APPLICATION OF PLASMA IGNITION SYSTEM IN THE 1000MW BOILER
wangruliang
Guodian zhejiang beilun power generation . Ningbo zhejiang.
ABSTRACT: This paper describes the is worth spreading in new — built power
design scheme for installing the plasma plants.
igniter on two,1000 Mw units in Phase—III
project of Guodian zhejiang beilun
KEY WORD: plasma ignition system boiler
power generation . . expounding the
influence
ensuing social , environment and economic
摘要:本文根据等离子点火装置在 1000MW 机组锅炉调试、启
be nefits . It introduces the problems
动和运行中实际应用的情况,分析了等离子点火装置应用中对锅
arising in the debugging process for plasma
ignition system. It arrives at a conclusion 炉安全、经济运行和环保方面的影响。针对存在问题,提出了解
that the plasma ignition bustion 决的方法和采取的措施,并简要分析了各种方法之间的经济性,
stabilizing technique is an effective 提出通过采取适当的措施,使等离子点火装置既达到了节油的目
measure to replace oil with coal in the
的,又使锅炉的运行更加安全,对周边环境的影响达到最小。
process of ignition bustion
stabilizing of pulverized coal 关键词:等离子装置;锅炉;影响
1 简述口温度为 378℃,进口压力为 ,再热器
流量为 。锅炉启动系统为带循环泵的
锅炉设备简介
启动系统,设计容量 25%BMCR,炉水循环泵采用
国电北仑电厂三期工程 2×1000MW 燃煤机
HAYWARD TYLER 公司产品。锅炉采用 HT-NR3 低
组锅炉本体是由东方锅炉(集团)股份有限责任
氮燃烧器,其中B 层 8 只燃烧器改为烟台龙源电
公司与日本巴布科克-日立公司及东方-日立
力技术有限公司设计生产的等离子点火燃烧器。
锅炉有限公司三方合作设计、联合制造的超超临
同步建设烟气脱硫和脱硝(SCR)