文档介绍:RCC-M - Edition 2000 Section III - MC
MC 1000
MECHANICAL, PHYSICAL,
PHYSICO-CHEMICAL AND CHEMICAL TESTS
MC 1100 GENERAL
This chapter describes test conditions and sets the dimensions for specimens.
MC 1110 SAMPLING METHOD
MC 1111 TEST MATERIALS
The location and orientation of specimens in the test samples are specified in SECTION II under
general provisions and technical specifications and shall be indicated in the documents issued by the
Manufacturer or materials Supplier.
MC 1112 WELDING
The location of test specimens is specified in annex S I to SECTION IV.
MC 1200 MECHANICAL TESTS
Test conditions and dimensions of specimens ply with AFNOR standards* referred to
below and with any modifications or additional specifications appearing in this chapter.
* Note : Titles of AFNOR standards have been translated for the RCC-M by Framatome.
MC 1210 TENSILE TESTS
Tension testing machines shall be verified as specified in standard NF EN . Machines used
shall be at least class 1.
Extensometers shall be verified as specified in standard NF EN ( extensometers used shall
be class 1 or better), or as specified in ASTM (extensometers used shall be class B2 or better)
n° 92-2000 MC 1000 / 1
RCC-M - Edition 2000 Section III - MC
MC 1211 TENSILE TESTING AT ROOM TEMPERATURE
Standards NF EN 10002-1 and NF EN 895 shall be applied taking the following remarks into
account:
A - NF EN 10002-1 "Tension testing (test method)".
ANNEX C
Specimen diameter shall be 10 mm (reduced section). Where a specimen of this diameter cannot
be procured, small specimens may only be used for information purposes or where explicit
provision is made for this possibility.
ANNEX D
Where the thickness of the tube (or fitting) allows, a test specimen with a diameter of 10 mm
shall be used. Otherwise, the test shall be performed on strips cut from th