Z170 静音箱式发电机组风冷散热器的设计与匹配
陈作俊1 ,王田纲2 ,王兆坤2
( 1. 山东理工大学交通与车辆工程学院,山东淄博 255049; 2. 淄博淄柴新能源有限公司,山东淄博 255088)
摘要: 本文对 Z170 静音箱式燃气发电机组用风冷散热器设计匹配过程中,主要的影响因素、设计计算及注意的事项进行了分析,并结合试验验证所用的设计参数、储备系数的准确性。
关键词: 静音箱; 发电机组; 风冷散热器; 设计匹配
中图分类号: TK432 文献标志码: A 文章编号: 1673 - 6397( 2014) 06 - 0016 - 02
Designing and Matching of Air Cooling Radiator with Z170 Attenuated and Enclosured Generator Set
CHEN Zuo - jun1 ,WANG Tian - gan2 ,WANG Zhao - kun2
( 1. School of Transportation and Vehicle Engineering,Shandong University of Technology, Zibo 255049,China; 2. Zibo Zichai New Energy Co. ,Ltd. ,Zibo 255088,China)
Abstract: This paper analyzes the main factors that have influences on designing and matching of the air - cooled radiator applied for Z170 attenuated and enclosure generator set,and discussed the design calculation and events that should be attended. The accuracy of the applied parameters, reserve factors is verified by tests.
Key Words: Attenuated Enclosure; Generator Set; Air Cooled Radiator; Design Matching
引 言
Z170 静音箱式燃气发电机组( 以下简称静音箱机组) 设计作为野外矿用电动机供电设备,现场无网电接入和补充水源。因此与其配套的该型风冷散热器需满足机组冷却系统的散热前提下,还应满足无电传动、耗水少、运行可靠的要求。
1 基本设计原则
风冷散热器主要包括冷却风扇、散热器、传动装置三部分,设计原则遵循以下几点:
a) 具有较强的散热能力,满足机组运行对冷却水、机油等温度指标的要求;
b) 采用机械传动方式;
c) 结构可靠,满足长时间连续运行要求。
2 静音箱机组冷却系统设计参数
表 1 机组冷却系统设计参数
名称/ 单位
参数
散热量/ kW
2