文档介绍:电力建设
第 31 卷第 1 期 ,
2010 年 1 月 Electric Power Construction Jan,2010 ·37 ·
中图分类号:TM 63 文献标志码:A 文章编号:1000-7229(2010)01-0037-03
GIS 组合电器的安装工艺和关键控制要点
李润春,王露钢,刁志昆
(吉林省送变电工程公司,长春市,130033)
bined Electrical Apparatus Installation Technology
and Key Control Points
LI Run-chun, WANG Lu-gang, DIAO Zhi-qun
(Jinling Provincial Transmission and Transformation pany, Changchun 130033, China)
ABSTRACT: bined electrical installation technology is 组合电器的特点
an important measures to ensure installation quality, and installation 1 GIS
scheme based on the apparatus’s features should posed to GIS 组合电器基本是由断路器、隔离开关、接地
guide their construction. Cleanness is the prior control
开关、电压互感器、电流互感器、避雷器、母线、连接件
requirement during installation, sealing is the key for GIS
等单元组成,这些单元均封闭在接地的金属罐体内。
long-term safe operation. The voltage withstand and partial
其内部充有一定压力的 SF 气体,SF 具有优异的灭
discharge tests should be required for GIS delivery and on-site. 6 6
弧和绝缘能力。由于 GIS 的构造既封闭又组合,故占
KEYWORDS: bined electrical apparatus; installation 地面积小,占用空间少,基本不受外界环境影响,不产
procedure; process requirements; key quality control point 生噪声和无线电干扰,运行安全可靠,且维护工作量
摘要: 组合电器安装工艺是保证安装质量的重要措施,需
GIS 少。它的突出优点是:
要针对设备特点编制有针对性的安装方案来指导施工。洁净度
(1)最大限度地缩小整套配电装置的占地面积
是安装中首要的控制要求,密封性是 GIS 长期安全运行的关
和空间体积,结构十分紧凑。在人口高度集中的大都
键,GIS 设备出厂和现场都要做耐压和局部放电试验。
市和密集的负荷中心,显得更为重要。
关键词: 组合电器;安装程序;工艺要求;质量控制要点
GIS (2)全封闭的电器结