文档介绍:有载调压分接开关过渡电阻选用设计
摘要:
本文通过介绍有载分接开关的基本工作原理及有载分接开关切换过程中暂态过程的建模来选用合适过渡电阻值,同时着重从几个方面(有利于改善触头的切换任务,提高触头的电气寿命以及其工作可靠性三个原则来进行匹配)来分析并从中筛选出最佳方案。这对于变压器设计者更深入的了解有载分接开关以及设计过程中考虑更为全面起到了一定的指导作用。
关键词:灭弧;有载调压开关;变压器
abstract:through the introduction of on-load tap basic working principle and the transient process on-load tap changer switching process modeling to choose a suitable transition resistance value at the same time focus from several aspects (help to improve the contact switch tasks, three principles to improve the contact electrical life as well as its operational reliability to match) to analyze and to filter out the best solution. for transformer designers a deeper understanding of the on-load tap switch as well as the design process to consider prehensive played a certain role in : interrupter; oltc; transformer
中图分类号:+1文献标识码:a文章编号:
引言
变压器通过调压线圈中增减绕组的分接头来改变电压比的方法几乎与变压器同时问世,有载调压开关的应用使得在不切断负载的情况下可以调节电压。
如今,有载调压分接开关已经由油中灭弧的方式向通过真空泡灭弧的方式发展。无论是工业用户还是电网用户为了缩小维护成本降低维护工作量,都对真空开关比较青睐。所以真空有载调压分接开关是当今以及未来的发展趋势。因此选用真空开关对节省维护成本,降低供电公司工作量也是非常有益的。
1 传统有载调压开关(例如m型)的作用及原理
一是在开路情况下
“选择”一个分接头,二是在不中断电流的情况下把功率“切换”或“调换”到所选的分接头上。而其中也有简易式有载分接开关(即:选择开关)是把两种功能结合在一个装置中,而分接选择器与切换开关或调换开关互相分开的分接开关是用于功率较高的情况下。
分接开关的基本要求及原理
分接开关必须要满足在分接选择器、转换选择器和切换开关或调换开关之间都要保持准确的机械同步。功率调换时所产生的电弧处于油中,从而污染了变压器油(用真空泡作为开关装置的有载分接开关除外)。所以开关装置需要放在它本身的油室中,以便把污染的油与变压器的主油箱分开。
选择开关的基本原理是