文档介绍:离心压缩机管系振动分析及减振措施
宋晓辉,范德顺,乔舰
(北京化工大学机电工程学院CAE中心,北京,100029)
摘要:针对离心压缩机管系振动十分强烈的情况,进行振动分析。利用CAESARⅡ和MATLAB软件分别对管系的机械固有频率和气柱固有频率进行计算,结合计算结果分析确定引起管系振动的主要原因,并提出减振措施,对减小现场管系的振动具有实际价值。
关键词:离心压缩机;管系振动;减振措施
Piping vibration analysis and measures of vibration damping of pressor
SONG Xiao-Hui, FAN De-Shun, QIAO Jian
(Beijing University of Chemical Technology Institute of Electrical and Mechanical Engineering, Beijing, 100029,China)
Abstract: In view of a strong piping vibration case of pressors to make a vibration analysis .Using of CAESARⅡ and MATLAB software calculate the piping of the Natural Frequency of the Mechanical and the Gas Columns ,combined with analysis of calculation results to determine the main reason for the piping vibration and to develop an effective measures of vibration damping, thus it has a practical value for piping vibration damping in the plant.
Keywords: pressor; piping vibration; measures of vibration damping
0 引言
离心压缩机管道振动存在两个不同的振动系统:一是机械振动系统,由管道、管道附件、容器、支架等构成,它受到激发后会产生机械振动响应。二是气柱振动系统,即充斥于管路内的气体,它可以压缩、膨胀,是一个连续质量的弹性振动系统,这个系统受到一定的激发后就会产生振动响应。对于管系的机械固有频率和气柱固有频率,如果有一个与激发频率接近就会产生共振,当激发频率等于气柱固有频率又等于管路的机械固有频率时,则气柱和管道均处于共振状态,导致管道发生更强烈的振动。在生产实际中,由于强烈的管道振动,将会使管路附件,尤其是管道的连接部位、管道与附件的连接部位和管道与支架的连接部件等处发生磨损、松动;在振动所产生的交变应力作用下,导致疲劳破坏,从而发生管线断裂、介质外泄,甚至引起严重的生产事故,给生产和环境造成严重危害[1],因此
只有采用科学的、正确的分析方法找出引起振动的主要原因才能采取合理的减振措施。本文应用CEASERⅡ管道应力分析软件和MATLAB程序法对一台离心压缩机出口管线进行建模分析,求