文档介绍:使用说明书压力/差压智能变送器
Operation instruction
目录
引言······························································(2)
运输······························································(3)
储藏······························································(3)
产品标识·························································(3)
工作原理·························································(4)
安装······························································(5)
电气连接·························································(7)
使用······························································(8)
菜单操作························································(9)
维护·····························································(27)
修理·····························································(27)
引言
智能压力/差压变送器是采用高精度硅传感器技术,新型智能高精度变送器,基于通过微处理器的电子部件,实现与现场设备通信。
压力/差压变送器包括表压、差压、绝对压力、高静压差压等多个品种。
广泛应用于石油、化工、电力、冶金、水务、酿造等工业领域。长期以来,以产品的卓越品质和优质的售后服务,赢得了用户一致的好评。
■运输
在校验之后,仪器被包装在纸箱(GB/T 13384-2008)中以保护免遭损伤。
■储藏
储藏仪器无需任何特殊处理。对储藏期没有限制,但保质期仍按公司规定的期限一致。
■产品标识
产品铭牌标识包括序列号、量程、精度等级、输入电压、输出、出厂日期等相关信息。
重要:查询时务必提供仪表序列号。
■工作原理
图1压力变送器包括两个功能单元:
—主单元
—辅助单元
主单元包括传感器和过程连接,工作原理如下:过程介质通过柔性、抗腐蚀性的隔离膜片以及填充液在测量膜片上施加压力,测量膜片的一端接大气(用于表压测量)或真空(用于绝压测量).当所测的压力通过测量膜片和填充液,传递给传感器硅芯片,使传感器硅芯片的阻值发生变化,, 图1 压力(绝压)变送器再由适配单元和放大器转化成一标准化
信号输出。
图2差压变送器包括两个功能单元:
—主单元
—辅助单元
主主单元包括传感器和过程连接,工作原理如下:传感器模块采用全焊接技术,内部拥有一个整体化的过载膜片,一个绝对压力传感器和一个差压传感器。绝压传感器只装在传感器膜盒的高压侧,作为静压补偿的参考值。 差压变送器
隔离膜片和填充液,传递给传感器硅芯片,使传感器芯片的阻值发生变化,从而导致检测系统输出电压变化。该输出电压与压力变化成正比,再由适配单元和放大器转化成一标准化信号输出。
安装
▲警告:为了确保操作员以及工厂的
安全,务必由经过培训的人员按照型号的技
术数据进行安装。
▲警告为了确保操作员以及工厂的安全,务必
由经过培训的人员按照型号的技术数据进行安装
变送器显示壳体可以相对传感器旋转约360度,而不影响性能和内部配线。不要强制旋转传感器部分,用2mm六角扳手来松开或锁定紧定螺钉。这样可对电子线路连接和输出显示器影响量达到最小。安装如下图所示:
图3压力变送器管道、墙面安装
图4差压变送器管道、墙面安装
为了正确安装,必须遵循以下几点:
引压管道尽可能短,并避免急弯折。
引压管道的安装坡度不应小于1:12,以免引起沉淀。
引压管道在连接到变送器前,必须用压缩空气吹一遍,最好用被测介质冲洗一遍。
如果介质是液体,则应彻底放空引压管道。
引压管道的布局,应使得被测液体中的气泡或被测气体中的沉淀