文档介绍:一体式膜—生物反应器处理医院污水
作者:丁杭军文湘华黄霞时间:2007-11-24 17:50:00 来源:论文天下论文网
论文作者:丁杭军文湘华黄霞刘若鹏刘锐
摘要:工程应用的结果表明,一体式好氧中空纤维膜—生物反应器用于处理医院污水在技术上是可行的,其对医院污水中的COD、氨氮、浊度的平均去除率分别可达80%、93%、83%,出水水质良好、稳定、无色无嗅,优于国家建设部颁发的医院污水排放标准。系统已稳定运行6个多月,膜阻力上升稳定、缓慢,其间没有对膜进行过任何清洗。
关键词:膜—生物反应器医院污水处理效果
 
Application of the Integrative Membrane-bioreactor for Treatment of Hospital Wastewater
Abstract:The results of engineering application of integrative hollow fiber membrane-bioreactor for treatment of hospital wastewater show that the use of this process for treatment of hospital wastewater is technically removal rate of 80%,93%,and 83% is achieved respectively for COD,NH3-N,and turbidity in hospital effluent is colorless and odorless with good and stable quality,and surpasses the hospital wastewater discharge standard issued by the ministry of system has run for more than 6 months without any chemical transmembrane pressure increases slowly and steadily.
Keywords:membrane-bioreactor;hospital wastewater;treatment efficiency
1 工程装置与污水水质
一体式膜—生物反应器处理医院污水的工程装置设在北京海淀乡卫生院内,设备的内部构造见图1,设计处理能力为20m3/d。
整个装置主要由生物反应池和膜组件组成。生物反应池采用好氧完全混合式活性污泥反应池,有效容积为6m3,设有隔板将其分为大小相等的两个池子,内置聚乙烯中空纤维膜组件24块,每块膜组件的面积为4 m2,膜总面积为96m2。膜组件下设有穿孔管曝气,曝气量控制在80~90m3/h。中空纤维膜采用间歇运行,抽吸频率为开13 min,关2 min。压差计用于监测膜过滤压力的变化。液位计控制活性污泥反应器液面的恒定。流量计用于测定膜出水的流量。
接种污泥取自北京高碑店污水处理厂二沉池回流污泥。污水先流入调节池,然后由泵提升经细筛网