文档介绍:ELECTRICAL INTERFACE BETWEEN INJECTION
EUROMAP
12 MOULDING MACHINE AND HANDLING DEVICE
Version July 2007 (11 pages)
This recommendation was prepared by the Technical Commission of EUROMAP ・ However, see also EUROMAP 67.
A further supplier added (v. ). Suppliers data amended (v. ).
Contents
1.
Scope and Application
2.
Description
Plug and socket outlet
Sv/itch contact specification
Plug contact assignment
3・
Ejector Sequence
4.
Core puller sequences
Ejector sequence with core puller
Core puller sequence for removal of
the
part
4・3
Core puller sequence for insertion
Core puller sequence for remova1 of
the
part and insertion
5.
Handling device power supply
6.
Sources of supply
page 2/11 EUROMAP 12 z Version , July 2007
EUROMAP 12 f Version , July 2007 page #/11
1• Scope and Application
This EUROMAP recommendation defines the connection between the injection moulding machine and the handling device. This is intended to provide interchangciabilitiy .
In addition recommendations are given for signal voltage and current levels. The mains connection of the handling device is also specified.
2 • DescriDtion
The signals in both the injection moulding machine and the handling device are given by contacts, . contacts of relays or switches, etc.. Tho contact making is either potential-free or related to a reference potential supplied to a contact of the plug mounted on the injection moulding machine or the handling device (see Cables 1 and 2).
The signals shall be available in all injection moulding machines and handling equipments.
Plug and socket outlet
The
connection between the injection moulding machine and the handling device is achieved by injection moulding machine the the plug contacts 17 be capable of taking
to 32 are a minimum
the plugs specified below. For the plug contacts 1 to 16 are male and female. All the plug conta