文档介绍:基站可换设备故障处理指南
修订记录
Date
Version
Issued By
Changes
30 May 2001
M. Schirmacher
Original
Table of Contents
1 目的 5
2 范围 5
3 参考资料及注意事项 5
4 载频常见故障说明 6
“DRI Not Detected”和“Waiting for Connection” 6
“Inhibited” 6
“Code Load Fail”和“CEB Configuration Fail” 6
“No HDLC reset pending” 7
“Code Load” 7
“Invalid Calibration Data” 7
“High call/set-up failure rate” 7
DRI 150 或“Receive Matrix Branch 1 Control Link Failure” 8
5 MCU/MCUF 常见故障说明 8
无LED指示 8
不能进行TTY接入 8
“Waiting for sync to initialize”出现在TTY 8
MCU/MCUF 连续不断的重新启动 9
“FMUX Loopback Failure” 9
“No Redundant Link” 9
“PCMCIA Failure” 9
6 现场工程师处理CTU和TCU-B的步骤 10
现场工程师执行的一般性检查 10
“DRI NOT DETECTED”& “Waiting for Connection” 11
“Inhibited” 11
“Code Load Fail”& “CEB Configuration Fail” 11
“No HDLC reset pending” 12
“Code Load” 13
“Invalid Calibration Data” 13
“High drop call/set-up failure rate” 13
DRI 150多或少告警或“Receive Matrix Branch 1 Control Link Failure” 13
7 现场对于MCU/MCUF问题的判断方法 15
对于 MCU/MCUF 问题的简要判断 15
没有灯指示 15
TTY 端口没有响应 15
“Waiting for Sync to initialize”提示出现在 TTY端口 16
MCU/MCUF 不停地重新启动 16
“FMUX Loopback Failure” 16
“No Redundant Link” 17
“PCMCIA Failure” 17
附录 A 18
现场工程师检查 CTU’S & TCU-B’S项目列表 18
附录 B 19
现场工程师对MCU/MCUF的检查清单 19
附录 C 21
使用PC卡与MCU/MCUF相连启站 21
使用 SET_SITE 命令。 21
目的
本文件应被用作在现场遇到故障时的快速参考工具。其中包括了大多数常见问题并提供了快速解答和可能的解决方案。通过下列方法,可以减少返修器件的数量,提高网络的整体可靠性。
范围
下列方法适用于所有现场工程师。
参考资料及注意事项
本文件要求对系统有一般了解,且系统已正确安装,并进行了适当的频率优化。关于下列方法的信息,请咨询当地摩托罗拉分公司或访问摩托罗拉内部网: ./General/sop/gsm/
本文中使用下列约定:.
黑斜体字代表输入的命令。
斜体字代表关于命令或输出的附加信息。
静电放电注意事项
在任何情况下处理电气设备都必须警惕以防止静电放电损伤。下列注意事项可以将发生静电放电的可能降低到最小:.
必须使用防静电腕带,且应将防静电腕带接至摩托罗拉设备上的防静电接地点。
在接触任何器件前应通过触摸机柜的金属表面释放静电。
如要接触电路板或数字卡,应只接触前面板或电路板的边缘。应避免接触电路板上的电路或器件。
载频常见故障说明
下文中提到的故障都是客户返修中最常见的,也是返修中最有可能发生“No-Fault-Found”情况的。通过了解造成这些故障的可能原因,用户就能在故障发生时确定故障背后的真正原因。这将减少网络故障时间并提