文档介绍:第三届 LNG 论坛论文编号:1240204
影响自吸离心泵自吸能力的因素及处理措施
胡锦武 1,2 冯道荣 1,3
(1. 广东大鹏 LNG 有限公司, 广东深圳 518034; 2. 华中科技大学, 湖北武汉 430074;
3. 长江大学, 湖北荆州, 434023)
摘要:对某牌子的清水自吸离心泵存在不能自吸的问题进行分析、并结合现场测量、改造和实验等一
系列工作,提出安装高度和配管情况对泵性能的影响。
关键词:自吸离心泵安装高度当量损失泵串联
The Affecting Factors and Handling Method of Self-Imbibitions’ Performance of Self-Priming
Centrifugal Pump
Hu Jinwu 1, 2 Feng Daorong 1, 3
(Guangdong Dapeng pany Ltd. Shenzhen 518034; 2. Huazhong University of Science and
Technology, Wuhan 430074; 3. Yangze University, Jingzhou 434023)
Abstract: To analyze the unable pumping problem of one brand self-priming centrifugal fresh water pump
herein, bined with a series of works including the site measurement, modification & experimentation,
then point that the pump erection position and pipe installation status will affect the pump’s running
performance.
Key words: Self-priming centrifugal pump Installation position Loss equivalent Pumps in series
离心泵自吸是指在泵吸入腔内保持少量液体的情况下启动泵,泵本身能自动排除吸入管内的气
体,而后进入正常工作。一般的,泵在初次启动时必须灌入足够液体,以后启动时则由存留在泵体内
的液体来保证泵再次启动后可以自吸液体。离心式自吸泵的允许安装高度对泵的自吸时间以及自吸效
果起着很重要的作用,过高的安装高度甚至使泵不能把水抽出。本文通过对我厂 14 台某品牌的雨水自
吸泵存在的问题进行描述,并采用其中的 2 台 P-8403A/B 进行测量、计算、分析和实验,提出影响自
吸离心泵自吸能力的因素和措施。
我厂现有 14 台某品牌的自吸泵,都采用水位高位(水位到泵入口距离为 3 米时)启动,低位
(水位到泵入口距离为 6 米时)自动停泵的自动起停方式,但自从 2006 年投产以来,大部分水泵无法
正常运行,主要是当水池的水位降到离泵入口约 的时候,即使给泵进行灌泵排气,也无法把水抽
起,更不能按要求自吸,当水位到泵入口距离小