文档介绍:摘要
火电厂热系统工况发生变动时,将会引起整个热系统和全厂的热经济性指标发生变动。本设计主要内容为某660MW凝汽式机组全厂原则性热力系统变工况计算,根据给定的热力系统及其数据,在热力系统常规计算方法的基础下,计算额定功率下,切除最后一级高压加热器H1时的系统中各点汽水参数、流量和热经济指标,以及分析其经济性。根据设计工况与变工况两组数据的计算结果作为运行和调控的依据。
关键词:原则性热力系统变工况常规法
Abstract
Thermal power plant thermal system conditions (parameters) change will cause the entire thermal system and heat the whole plant changes in economic indicators. The main elements of the design for a 660MW unit condensing steam plant thermal system in principle calculation of variable condition, according to a given thermal system and its data to calculate the rated power, when the removal of the last level at the time of high-pressure heater system H1 soft drinks all parameters, flow and thermal economic indicators. By ordinary methods and equivalent enthalpy drop method pare the calculation of the two conditions of thermal economy, in order to provide the basis for the operation and regulation.
Key words :Principle Thermal System Changes the operating mode Equivalent enthalpy drop 
目录
第一章绪论 1
第二章热力系统原则性计算原理 2
2
3
第三章机组全厂原则性热力系统计算 5
热力系统与计算原始资料 5
汽水平衡计算 9
汽轮机进汽参数计算 9
辅助计算 10
各加热器进、出水参数计算 11
高压加热器组抽汽系数计算 14
除氧器抽汽系数计算 15
低压加热器组抽汽系数计算 16
凝汽系数计算 17
第四章机组全厂原则性热力系统变工况计算 19
原始工况计算 19
第一次迭代的预备计算 22
第一次迭代计算 28
第二次迭代计算 34
第三次迭代计算 44
全厂热经济指标计算 45
第五章结论 47
谢辞 48
参考文献 49
第一章绪论
火电厂热系统的变工况是指系统的工作条件(参数)发生变动,偏离设计工况或都偏离某一基准工况。这种偏离大致辞有二种情况:一是对热系统的结构进行了某种局部改动;二是热系统本身的结构未加改动,但是系统运行条件发生了变化。前者的例子如去除某一级加热器运行等,不论哪一种形式的工况变动,结果都将引起整个热系统的参数的变化,从而导致机组的和全厂的热经济指标发生变动。
在电厂的设计和运行中,全厂热力计算主要解决两类问题:一是经计算给出若干工况下全厂的热经济性指标,如全厂发、供电煤耗率,全厂热效率,全厂节煤量等;二是为电厂的设计、运行、机组检修等提供基础数据,如汽轮机组以及各汽、水管道的汽水流量。
设计工况的指标是所有工况中最具有代表性的,因此设计工况下的全厂热力计算是最为普遍、也是最为基本的计算。在设计和最大工况下进行计算所得到的各部分汽水流量,是选择机组辅助热力设备和汽水管道的重要依据。在进行其他一些工况计算(即变工况计算)时设计工况的计算结果往往就为它们提供初始的计算依据。
热系统变工况计算的目的,是确定汽轮机在新的工况下各抽汽口和排汽端的蒸汽参数,以及回热给水系统各参数及流量,其实质是确定汽轮机的新的汽态膨胀过程线和系统参数。
热力系统的变工况计算是以级组(两个抽汽口之间的各级)为单位进行的。计算时只需要了解各抽汽口的参数变化而不必知道汽轮机各级详细工况。
较为精确的