文档介绍:Door switch
Open circuit
Intermittent circuit
Inoperable dishwasher
Electrical shock
10
10
10
10
10
10
10
10
Connection of 14 gage power leads to top of door switch
Insufficient length of power leads exiting tape point in harness
Excessive pulling on power leads to provide length necessary to connect dishwasher to manufacturing pallet
Excessive pulling on power leads to provide length necessary to connect dishwasher during installation
Ratcheting if harness downward as dishwasher door is opened and closed
Insufficient overall length of power leads
Power leads severed by pinch point on door latch
Power leads severed by console mounting screw
7
8
3
5
4
9
6
3
Have instructed production employees to connect power leads to bottom of door switch
Notified burcliff on 2/4/91 to tape power leads in 5” from tape point on all harness
Timer block bears the load under normal circumstances
Timer block bears the load under normal circumstances
None
Length is specified on drawing
Production employees are dressing leads away from latch when consoles are attached to doors
Production employees are dressing leads away from screw hole when consoles are
9
3
9
10
10
3
8
9
630
240
270
500
400
270
480
270
Shorten door switch leads that go to top of door switch on a harness by harness basis
Study issue of length on a console by console basis
Find