文档介绍:XXX项目PHC桩基施工方案XXX项目PHC桩基施工方案编制人:审核人:审批人:日期:XXXX项目部1XXX项目PHC桩基施工方案目录一、编制依据...................................................1二、工程概况...................................................1三、施工准备.......................................................................................................................................................................................................................................3四、静压预应力管桩施工.......................................................................................................................................................................................8五、桩检方式..............................................................................................................................................13六、安全保护措施..............................................14七、质量保证措施..................................................................................................................................................................................................152XXX项目PHC桩基施工方案一、编制依据序号名称编号1《工程测量规范》GB50026-20072《建筑地基基础工程施工质量验收规范》GB50202-20023《建筑工程施工质量验收统一标准》GB50300-20014《建筑地基基础设计规范》GB50007-20115《建筑桩基技术规范》JGJ94-20086《建筑基桩检测技术规范》JGJ106-20037《预应力混凝土管桩》10G4098本工程施工组织设计9本工程设计图纸二、工程概况序号项目内容1项目名称2工程地址3建设单位4设计单位5总承包单位6监理单位本次施工范围为XXXXXX采用预制PHC预应力混凝土管桩,桩尖采用钢板制作,采用十字形桩尖。贯入类型采用静压方式。管桩桩径400mm,壁厚95mm,AB型桩。桩身混凝土等级为C80,总根数为358根。本工程±,ZH-1桩顶设计标高为:-,有效桩长约为38;m;ZH-2桩顶设计标高为:-,-,有效桩长为1XXX项目PHC桩基施工方案34m;ZH-3桩顶设计标高为:-,有效桩长为34m。ZH-1预应力管桩单桩竖向承载力特征值为800KN,桩基础以全风粗砾砂为持力层,;ZH-2、ZH-3预应力管桩单桩竖向承载力特征值550KN,桩基础以粉质黏土为持力层,。三、(1)处理施工场地内影响压桩的上空及地下障碍物。(2)平整及处理施工场地,达到地面平整、排水通畅、坡度不大于2%。对于可能不适合压桩机正常运行的松软场地应作处理,使场地的承压能力能满足压桩机正常运行的要求。(3)在不受施工影响的地方设置基桩轴线的控制点和水准基点,且标记明显并作好保护。(4)施工现场必要的工作人员到位、配套工种齐备。并向施工人员进行技术安全交底。