文档介绍:2
1
1 1
2
2 2主换热器2 效2 率下降导致空分设备
被迫停车的分析与处理
张强, 吴秉功
(永钢集团有限公司制氧分厂, 江苏省张家港市南丰镇永联工业区 215628)
摘要: 介绍了永钢 21000m3 / h 空分设备因主换热器换热效率下降而被迫停车故障的经过, 分
析后得出原因为: 空压机泄漏的润滑油进入主换热器并冻结成油薄膜, 使换热系数降低, 最后阐
述了处理过程。
关键词: 大型空分设备; 主换热器; 换热效率; 油脂; 清洗; 加温
中图分类号: TQ116 11 文献标识码: B
Analysis and treatment of forced shutdown of air separation unit due
to inefficient operation of main heat exchanger
Zhang Qiang , Wu Bing gong
[ Oxygen Producing Factory , Yonggang ( Group) Co , Ltd , Yonglian Industrial Zone , Nanfeng Town ,
Zhangjiagang 215628 , Jiangsu , P. R. China ]
Abstract : The course of forced shutdown of 21000m3 / h air separation unit in Yonggang due to the inefficient main heat
exchanger is introduced. The cause analysis indicates that the decrease in the efficiency of main heat exchanger origined
from a leak of lubricant from pressor , then entering main heat exchanger and frozen into solid oil film. Finally ,
the treating measures and modification procedures are described.
Keywords : Large scale air separation plant ; Main heat exchanger ; Heat transfer efficiency ; Grease ; Cleaning ; Heating
永钢集团有限公司(以下简称: 永钢) KDON 1 主换热器故障经过
21000/ 21000 型空分设备由杭氧设计制造, 采用分
2007 年 4 月 22 日凌晨, 开始出现主冷液位无
子筛吸附净化、增压透平膨胀机、规整填料上塔及
法维持稳定且不断下降, 冷量不足的现象。经检查
全精馏无氢制氩技术。于 2007 年 3 月进入调试阶
确认膨胀机工作正常, 但主换热器热端 4 个温度点
段, 4 月 12 日正式生产出合格的产品氧、氮。2007
的温度波动, 主换热器热端温差从正常的 2 ℃~
年