文档介绍:大体积混凝土承台施工温度裂缝控制
大体积混凝土承台施工温度裂缝控制
摘要:大体积混凝土施工时,在砼硬化期间水泥会释放出大量水化热,致使内部温度不断上升,砼表面和内部温差较大,容易产生温度裂缝,影响结构安全和正常使用。如何控制温度裂缝是大体积混凝土施工的关键所在,下面以江顺大桥Z3号、Z4号墩承台及塔座为例,阐述大体积承台砼施工温度控制技术。
关键词:混凝土;温度裂缝;控制
Abstract: mass concrete construction, during the period of concrete hardening cement can release a large number of hydration heat, the internal temperature rising, the concrete surface and internal temperature difference is bigger, is easy to produce temperature crack affect the structural safety and normal use. How to control the temperature cracks of mass concrete construction is the key, the following number with number Jiang Shun Bridges Z3 and Z4 pier caps and tower as an example, the temperature control during the construction of large volume concrete cofferdam is introduced.
Key words: reinforced concrete; Temperature crack; control.
中图分类号:TV544+.91文献标识码:A文章编号:2095-2104(2013)
江顺大桥Z3号、Z4号墩承台基础为圆哑铃型,×,。承台设计为C40号混凝土,单个承台混凝土方量为l0205m3。各承台顶均设2个塔柱底座,塔座为八角棱柱形,×20m,×l4m,厚度为3m。塔座设计为C40号混凝土,。
承台及塔座的施工时间刚好在7~8月份,气温约为25~32℃,天气炎热,浇筑温度较难控制。况且这期间广东将进入台风季节,风力较大,易带走混凝土表面的水分,造成塑性开裂,所以混凝土表面保温保湿养护尤其为重要。在混凝土施工中,将从混凝土的原材料选择、配比设计以及混凝土的拌和、运输、浇筑、振捣、通水、养护、保温等全过程进行控制,具体措施如下:
一、混凝土配制
为使大体积混凝土具有良好的抗侵蚀性、体积稳定性和抗裂性能,混凝土配制按如下原则配制:
1、采用低水化热的胶凝材料体系;
综合考虑混凝土绝热温升、收缩、强度、工作性等因素,优选绝热温升低、收缩低、抗拉强度高、施工性能好的配合比。
2、选用优质聚羧酸类缓凝高性能减水剂;
3、掺加