文档介绍:第 6 章:基本应用指令
T........................................... 6-2
C.......................................... 6-5
SET ...................................... 6-8
RST ...................................... 6-10
0: MC........................................ 6-12
1: MCE ..................................... 6-14
2: SKP ...................................... 6-15
3: SKPE .................................... 6-17
4: DIFU..................................... 6-18
5: DIFD..................................... 6-19
6: BSHF .................................... 6-20
7: UDCTR ................................. 6-21
8: MOV ..................................... 6-23
9: MOV/ .................................. 6-24
10: TOGG ................................... 6-25
11:(+) .................................. 6-26
12:(-) .................................. 6-27
13:(*) .................................. 6-28
14:(/) .................................. 6-30
15:(+1) ................................. 6-32
16:(-1) ................................. 6-33
17: CMP ..................................... 6-34
18: AND...................................... 6-35
19: OR........................................ 6-36
20:→BCD .................................. 6-37
21:→BIN.................................... 6-38
6-1
基本应用指令
一般定时器
T T
(TIMER)
指令说明
操作数
Tn:定时器号码,为储存累计的计时
时间(即当前值 CV)。
PV:( Preset Value)为定时器的设定
值。
TB:时基( Time Base),有 ,,1S 三种。
范围
WX WY WM WS TMR CTR HR IR OR SR ROR DR K
操作数
WX0 WY0 WM0 WS0 T0 C0 R0 R3840 R3904 R3968 R5000 D0 0
∣∣∣∣∣∣∣∣∣∣∣∣∣
WX240 WY240 WM1896 WS984 T255 C255 R3839 R3903 R3967 R4167 R8071 D4095 32767
Tn ○
PV ○○○○○○○○○○○○○
●定时器总数为 256 个(T0~T255),共有 秒、 秒、1 秒三种时基(Time Base)。
PLC 在出厂时已将这三种时基的定时器的个数、编号分配如下:【如果这不符需要可以利
用〝结构配置〞(CONFIGURATION)功能自行调整】。
T0~T49: 秒定时器(设定值 ~ 秒)。
T50~T199: 秒定时器(设定值 ~ 秒)。