actively carry out the law on civil air defense education, drawn out of the air defense in Pinglia Pingliang city Building under easy fare, daily special inspection and regulation, overfulfilled the province upper and lower knots of up to 500,000 yuan fee collection tasks. 5, further standardize internal management, improve staff quality. Adhere to the
actively carry out the law on civil air defense education, drawn out of the air defense in Pingliang city Building under easy fare, daily special inspection and regulation, overfulfilled the province upper and lower knots of up to 500,000 yuan fee collection tasks. 5, further standardize internal management, improve staff quality. Adhere to the
指示灯亮报警,不加热--R473和R551,阻值是32K和220K。32K换成24K。220K换成75K 10-苏泊尔C21S12-A出现间歇性加热,将4UF电容加到8UF后OK。-苏泊尔C21A01-B-DL02-A0这款主板E0是10K的电阻坏。12-苏泊尔c19s05-a出现E2,在热敏电阻上并一个200-300K左右的电阻。苏泊尔电磁炉常见故障代码E0内部线路故障E1无锅具或锅具不适用于电磁炉E2 IGBT功率管过热保护E3过载保护(一般是电压高于253V)E4欠压保护(一般是电压低于175V)E5传感器开路E6炉面温度过热保护
追问:
我都看晕了 我只要苏泊尔C21S02-A(黑)C电磁炉出E3的故障原因
回答:
E3过载保护(一般是电压高于253V)